Top of page. Skip to main contents. Skip to main menu. Skip to footer.

HOME > Products > Energy > MGS-HV series > Gen set rating
Main contents start here.

Gen set rating

50 Hz Stand-by Rating Selection Table
GEN SET MODEL ENGINE MODEL   3.3 kV 6.6 kV 10 kV 11 kV
MGS2500HV S16R-PTAA2 kVA 2250
pdf download
2250
pdf download
2250
pdf download
2250
pdf download
MGS2000HV S16R-PTA2-S kVA 2200
pdf download
2200
pdf download
2200
pdf download
2200
pdf download
MGS1500HV S16R-PTA-S kVA 2000
pdf download
2000
pdf download
2000
pdf download
2000
pdf download
MGS1400HV S12R-PTA2-S kVA 1575
pdf download
1600
pdf download
1600
pdf download
1600
pdf download
MGS1200HV S12R-PTA-S kVA 1475
pdf download
1475
pdf download
1475
pdf download
1475
pdf download
MGS1000HV S12H-PTA-S kVA 1225
pdf download
1225
pdf download
1225
pdf download
1225
pdf download


50 Hz Prime Rating Selection Table
GEN SET MODEL ENGINE MODEL   3.3 kV 6.6 kV 10 kV 11 kV
MGS2500HV S16R-PTAA2 kVA 2000
pdf download
2000
pdf download
2000
pdf download
2000
pdf download
MGS2000HV S16R-PTA2-S kVA 1900
pdf download
1900
pdf download
1900
pdf download
1900
pdf download
MGS1500HV S16R-PTA-S kVA 1700
pdf download
1725
pdf download
1725
pdf download
1725
pdf download
MGS1400HV S12R-PTA2-S kVA 1380
pdf download
1380
pdf download
1380
pdf download
1380
pdf download
MGS1200HV S12R-PTA-S kVA 1280
pdf download
1280
pdf download
1270
pdf download
1270
pdf download
MGS1000HV S12H-PTA-S kVA 1050
pdf download
1050
pdf download
1040
pdf download
1040
pdf download


50 Hz Continuous Rating Selection Table
GEN SET MODEL ENGINE MODEL   3.3 kV 6.6 kV 10 kV 11 kV
MGS1500HV S16R-PTA-S kVA 1560 1550 1540 1540
MGS1200HV S12R-PTA-S kVA 1140 1140 1130 1130
MGS1000HV S12H-PTA-S kVA 940 945 935 935


60 Hz Stand-by Rating Selection Table
GEN SET MODEL ENGINE MODEL   3.3 kV 4.16 kV 6.6 kV 13.8 kV
MGS2500HV S16R-PTAA2 kW 2000
pdf download
2000
pdf download
2000
pdf download
2000
pdf download
MGS2000HV S16R-PTA2-S kW 1850
pdf download
1920
pdf download
1850
pdf download
1850
pdf download
MGS1500HV S16R-PTA-S kW 1575
pdf download
1700
pdf download
1575
pdf download
1575
pdf download
MGS1400HV S12R-PTA2-S kW 1420
pdf download
1420
pdf download
1410
pdf download
1410
pdf download
MGS1200HV S12R-PTA-S kW 1270
pdf download
1270
pdf download
1260
pdf download
1260
pdf download
MMGS1000HV S12H-PTA-S kW 1070
pdf download
1070
pdf download
1070
pdf download
1060
pdf download


60 Hz Prime Rating Selection Table
GEN SET MODEL ENGINE MODEL   3.3 kV 4.16 kV 6.6 kV 13.8 kV
MGS2500HV S16R-PTAA2 kW 1800
pdf download
1800
pdf download
1800
pdf download
1800
pdf download
MGS2000HV S16R-PTA2-S kW 1650
pdf download
1650
pdf download
1640
pdf download
1640
pdf download
MGS1500HV S16R-PTA-S kW 1460
pdf download
1470
pdf download
1460
pdf download
1460
pdf download
MGS1400HV S12R-PTA2-S kW 1225
pdf download
1230
pdf download
1220
pdf download
1220
pdf download
MGS1200HV S12R-PTA-S kW 1080
pdf download
1080
pdf download
1070
pdf download
1070
pdf download
MGS1000HV S12H-PTA-S kW 930
pdf download
920
pdf download
920
pdf download
910
pdf download


60 Hz Continuous Rating Selection Table
GEN SET MODEL ENGINE MODEL   3.3 kV 4.16 kV 6.6 kV 13.8 kV
MGS1500HV S16R-PTA-S kW 1250 1250 1240 1240
MGS1200HV S12R-PTA-S kW 920 920 910 900
MGS1000HV S12H-PTA-S kW 830 830 820 810


Notice:-For other voltage and overload requirement, please consult with your nearest Mitsubishi MGS dealer.
-Photographs are with option devices.
-Specifications are subject to change without prior notice.

Rating Definition

Stand-by: Code: S
Applicable for supplying emergency power at varying load in the event of normal utility power interruption. Fuel stop power in accordance with ISO15550, ISO3046/1, JISB8002-1, DIN6271 and BS5514.
Prime: Code: CP
Applicable for supplying power with varying load instead of the utility for an unlimited time. Prime power in accordance with ISO 8528.
Continuous: Code: C
Applicable for supplying power continuously. Continuous power in accordance with ISO8528, ISO15550, ISO3046/1 JISB8002-1 and BS5514.
Conditions:
Engine ratings are based on SAE J1349 standard conditions and also apply at ISO3046/1, DIN6271 & BS5514 standard conditions.
Fuel rates: based on ASTM D975, BS2869 and on fuel oil of 35° API (16°C or 60°F) gravity having a LHV of 42,780 kJ/kg (18,390 Btu/lb.) when used at 29°C (85°F) and weighing 838.9 g/liter (7.001 lbs./U.S. gal.).
Note:The data or technical brochure on this website shows standard specification of MGS Generator set series and final scope and
specification will be decided by MHI/MHI Regional offices and their local dealers.

Get Adobe Reader Download Adobe Reader
To view Adobe Portable Document Format (PDF) files, you need the free Adobe Reader software from Adobe Systems Incorporated. By installing Adobe Reader you can view and print PDF files.Adobe and Adobe logo are trademark of Adobe Systems Incorporated.
Return to top.
Page Top