Supply Result
| Year | Customer | Equipment Name | Specifications |
|---|---|---|---|
| 1954 | For our company | 2m Low Speed Wind Tunnel | Type: Gottingen Measuring Section: 2 × 1.8m Octangular Max. Wind Velocity: 110m/s |
| 1955 | For our company | 1m Low Speed Wind Tunnel | Type: Gottingen Measuring Section: 1.0m Octangular Wind Velocity: 18 to 55m/s |
| 1955 | For our company | Cascade Wind Tunnel | Type: Boundary Layer Eliminating Type Low Speed Wind Tunnel Measuring Section: 650 × 300mm Wind Velocity: 10 to 60m/s |
| 1955 | For our company | Cascade Wind Tunnel Smoke Diffusion Small Wind Tunnel | Type: Blow-off Measuring Section: 0.55m × 1.8m Wind Velocity: 0.2 to 10m/s |
| 1956 | For the university | 1m Low Speed Wind Tunnel | Type: Gottingen Measuring Section: 1.0m Octangular Wind Velocity: 18 to 55m/s |
| 1957 | For our company | Vertical Wind Tunnel | Type: Blow-off Blower Rotor Dimensions: 1.0 × 1.0m × 1.2m Wind Flow Rate: 96m³/min |
| 1958 | For the university | 1m Low Speed Wind Tunnel | Type: Gottingen Measuring Section: 1.0m Octangular Wind Velocity: 20 to 62m/s |
| 1958 | For our company | Low Speed Single Wind Tunnel | Type: Blow-off Measuring Section: 0.215 × 1.0m Wind Velocity: 5 to 60m/s |
| 1960 | For the laboratory | Wave Generating & Flow Visualization Wind Tunnel | Type: Blow-off, Changeover Type Measuring Section: 800 × 800mm (Wave Generating Wind Tunnel) φ800mm (Flow Visualization Wind Tunnel) Max. Wind Velocity: 50m/s |
| 1960 | For our company | Vertical Wind Tunnel | Type: Blow-off Blower Rotor Dimensions: 1.2 × 1.2 × 1.2m Wind Flow Rate: 140m³/min |
| 1961 | For our company | 60cm- Straightened Wind Tunnel | Type: Blow-off Measuring Section: 600 × 600mm Wind Velocity: 0 to 42m/s Blower: Controllable-Pitch Rotor Blades |
| 1961 | For our company | Steel Tower Testing Wind Tunnel | Type: Blow-off Measuring Section: 3 × 1m Wind Velocity: 7 to 12m/s Velocity Distribution Controller & Pulse Generator are attached |
| 1962 | For our company | Gottingen Type Wind Tunnel | Measuring Section: φ1.5m Wind Velocity: 5 to 40m/s (Max. 80m/s) |
| 1963 | For the laboratory | Large-Size Low-Speed Wind Tunnel | Type: Closed Circuit Closed and Open Measuring Section Jet Type Measuring Section: 6.5 × 5m Max. Wind Velocity: 60m/s Blower Controllable-Pitch Rotor Blades Wind Flow Rate: 2,020m³/s |
| 1963 | For the university | Compressor Blade Element Test Facility(Vibrating Cascade Wind Tunnel) | Type: Vibrating Cascade Wind Tunnel (Fluid: Fresh Water) Measuring Section: φ360mm Normal Fluid Velocity: 5m/s Cascade Vibration: 1 to 10 cycle/s Swing: ±5mm |
| 1963 | For our company | Smoke Diffusion Middle-Size Wind Tunnel | Type: Blow-off Measuring Section: 2.5m × 1m × 15m Wind Velocity: 0.2 to 15m/s |
| 1964 | For the company | Automobile Engine Cooling Test Wind Tunnel | Type: Blow-off Measuring Section: 1.1 × 1m Rotation Speed: 1,170min-1 Wind Velocity: 4 to 38m/s Blower: Controllable-Pitch Rotor Blades |
| 1964 | For the university | Controllable Wind Direction Wind Tunnel | Type: Blow-off Measuring Section: 1.94m Octangular Rotation Speed: 590 rpm Wind Velocity: 0.5 to 40m/s Angular Range of WindDirection Control: 110° Blower Controllable-pitch rotor blades |
| 1964 | For the university | Cascade Experimental Facility | Type: Aligned or Curved Cascade Experimental Facility (Fluid: Fresh Water) Measuring Section, Straight Cascade Testing Section: 120 × 250mm Curved Cascade Testing Section: 305-dia Fluid Velocity: 0.5 to 5 m/s Curved Cascade Testing Section: 50m3/s |
| 1964 | For our company | Low-Speed Single Wind Tunnel | Type: Blow-off Measuring Section: 0.4 × 1.0m Wind Velocity: 5 to 60m/s |
| 1964 | For our company | Middle-Size Smoke Diffusion Wind Tunnel | Type: Blow-off Measuring Section: 2.5 × 1.0 × 15m Wind Velocity: 0.2 to 15m/s |
| 1965 | For the laboratory | Smoke Pollution Experimental Wind Tunnel | Type: Blow-off Measuring Section: 1.5 × 3 × 12m Wind Velocity: 0.2 to 15m/s Blower: Controllable-Pitch Rotor Blades |
| 1965 | For the university | Flutter Wind Tunnel | Type: Blow-off Measuring Section: 1m Octangular Wind Velocity: 7 to 50m/s Blower: Controllable-Pitch Rotor Blades |
| 1965 | For the university | Gottingen Type Wind Tunnel | Type: Closed Circuit Open Measuring Section Jet Type Measuring Section: 400 × 400m Square Wind Velocity: 2 to 40m/s |
| 1965 | For the university | Smoke Pollution Testing Wind Tunnel | Type: Suction Measuring Section: 1.5 × 2.5 × 6m Wind Velocity: 0.1 to 25m/s Blower: Controllable-Pitch Rotor Blades |
| 1965 | For the university | Gottingen Type Wind Tunnel | Type: Closed Circuit Open Measuring Section Jet Type Measuring Section: 1.5m Octangular Wind Velocity: 8.5 to 50m/s |
| 1966 | For the university | Gottingen Type Wind Tunnel | Type: Pressure-Controllable Closed Measuring Section Gottingen Type Measuring Section: φ250mm Wind Velocity: 2.5 to 50m/s |
| 1966 | For our company | Large-Size Smoke Diffusion Wind Tunnel | Type: Blow-off Measuring Section: 3 × 2 × 25mm Wind Velocity: 0.2 to 15m/s |
| 1967 | For the university | Structure Testing Wind Tunnel | Type: Closed Circuit Open Measuring Section Jet Type Measuring Section: 1,200 × 900mm Wind Velocity: 3.5 to 35m/s |
| 1967 | For our company | Slow Velocity Wind Tunnel | Type: Suction Measuring Section: φ100 Wind Velocity: 0.1 to 1.4m/s |
| 1968 | For the laboratory | Wide Area Pollution Simulating Wind Tunnel | Type: Blow-off Measuring Section: 1,800 × 4,600mm Wind Velocity: 2 to 12m/s |
| 1968 | For the university | Typhoon Disaster Experimental Wind Tunnel | Type: Closed Circuit Closed Measuring Section Jet Type Measuring Section: 4 × 2 × 6m Wind Velocity: 0.1 × 50m/s Pulse Generator is attached Blower Outlet Rotates 90° |
| 1968 | For the university | Assay Wind Tunnel | Type: Suction Measuring Section: 1 × 1m Wind Velocity: 0.1 to 50m/s Pulse Generator is attached |
| 1968 | For the university | Vertical Wind Tunnel | Type: Blow-off Measuring Section: 1,600mm Hexadecagonal Wind Velocity: 2 to 12m/s |
| 1969 | For the laboratory | Unsteady Aerodynamic Force Wind Tunnel | Type: Blow-off Measuring Section: 1,000 × 2,000 × 3,000mm Wind Velocity: 1 to 25m/s |
| 1969 | For our company | Assay Wind Tunnel | Type: Blow-off Measuring Section: 3 × 2 × 25m Wind Velocity: 0.2 to 15m/s |
| 1971 | For the laboratory | 400mm Low Speed Wind Tunnel | Type: Closed Circuit Open Measuring Section Jet Type Measuring Section: 400 × 400mm Wind Velocity: 12 to 36m/s |
| 1971 | For the university | Vortex-less Low-Speed Wind Tunnel | Type: Closed Circuit Open Measuring Section Jet Type Measuring Section: 1,750mm Equilateral Octangular Wind Velocity: 3.4 to 34m/s |
| 1971 | For the laboratory | Gust Tunnel | Type: Open and Closed Measuring Section Jet Type Measuring Section: 2,000 × 2,000 Square Wind Velocity: 3 to 50m/s (Normal), 67m/s (Max.) Gust Generator is attached Vibrator Frequency: 0 to 20Hz Balance Elevator Capacity: 5,000kg |
| 1972 | For our company | Wind Resistance Testing General-Purpose Diffusion Wind Tunnel | Type: Blow-off Measuring Section: 3m × 10m Wind Velocity1 to 25m/s |
| 1973 | For the company | Construction Materials Testing Wind Tunnel | Test Sample Maximum Dimensions: 6,000 × 7,000mm Static Pressure Range: Pmax.±133kPa Pulse Pressure: Maximum 47kPa, Intervals: 2s |
| 1974 | For the company | Construction Testing Wind Tunnel | Type: Closed Circuit Open and Closed Measuring Section Jet Type Measuring Section: 2,000 × 3,000mm Wind Velocity: 0.3 to 50m/s Balance Elevator Capacity 3,000kg |
| 1975 | For the company | Construction Materials Testing Wind Tunnel | Test Sample Maximum Dimension Large Size Wind Tunnel: 6,000 to 9,000mm Small Size Wind Tunnel: 4,000 to 3,000mm Static Pressure Range: Pmax.±133kPa Pulse Pressure P±P/2, Maximum 67kPa, Interval 2 seconds Vibration Max. Output: 5 tons, Swing: ±90mm, Intervals: 2s |
| 1976 | For the laboratory | Monroe Effect Research Wind Tunnel | Measuring Section: 2,000 × 1,500mm Measuring Section Length: 3,000mm Wind Velocity: 4 to 13m/s All Aluminum Structure |
| 1977 | For the laboratory | Air Pollution Experimental Wind Tunnel | Type: Open Measuring Section Suction Type Measuring Section: 3,000 to 6,000mm Measuring Section Length: 24,000mm Wind Velocity: 0.2 to 15m/s Blower Capacity: 270m³/s Effective Pressure: 11kPa |
| 1977 | For the laboratory | Flutter Wind Tunnel | Type: Gottingen Single Circuit Horizontal Type Measuring Section: 2,500 × 4,000mm Measuring Section Length: 10,000mm Wind Velocity: 1 to 25m/s Blower Capacity: 242m³/s Effective Pressure: 60mmAq |
| 1978 | For the university | Multi Purpose Wind Tunnel | Type: Open Measuring Section Blow Type Measuring Section: 1,500 × 1,500m Measuring Section Length: 4,000mm Wind Velocity: 0.5 to 15m/s |
| 1978 | For the company | Construction Materials Testing Wind Tunnel | Test Sample Maximum Dimensions: 3,600 × 2,500mm Static Pressure Range: ±67kPa Pulse Pressure: P±10kPa (Pmax=47kPa) |
| 1980 | For the university | Research Wind Tunnel | Type: Dual Purpose Gottingen and Blow-off Type Wind Velocity Blower Outlet I Dimensions: 1,800 × 1,800mm Wind Velocity: 2 to 20m/s Blower Outlet II Dimensions: 1,200 × 1,200mm Wind Velocity: 5 to 50m/s Blower Outlet III Dimensions: 1,800 × 1,800mm Wind Velocity: 1 to 10m/s |
| 1980 | For the laboratory | Wind Tunnel | Type: Gottingen Type Free Wall Blower Outlet I Dimensions1,400: 1,400mm Wind Velocity: 1 to 45m/s Free Wall Blower Outlet II Dimensions: 750 × 750mm Wind Velocity: More Than 50m/s Free Wall Blower Outlet III Dimensions: 1,400 × 1,400mm Wind Velocity: 1 to 48m/s Pulse Flow Wave Form: Sinusoidal Average Velocity: Maximum 40m/s Frequency: 0.2 to 2 Hz Velocity Stratification Velocity Ratio Upper: Lower=1:1.4 Average Velocity: Maximum 30m/s |
| 1982 | For the university | Multi Purpose Gottingen Type Wind Tunnel | Type: Gottingen Type Measuring Section: 800 × 800 × 3,000mm Wind Velocity Fixed Wall: 5 to 45m/s Free Wall: 5 to 40m/s Chiller is attached |
| 1985 | For the university | Gottingen Type Wind Tunnel | Type: Gottingen Type Horizontal Blower Outlet Dimensions: 1.0 × 1.0m Wind Velocity: 2 to 43m/s 6-Component Balance is Attached |
| 1985 | For the university | Multi Purpose Gottingen Type Vertical Wind Tunnel | Type: Gottingen Type Vertical Blower Outlet Dimensions: 600 × 600mm Wind Velocity: 1 to 50m/s |
| 1986 | For the university | Gottingen Type Wind Tunnel | Type: Gottingen Type Horizontal Blower Outlet Dimensions: 1,000 × 1,000mm Wind Velocity: 5 to 50m/s 6-Component Balance is Attached |
| 1987 | For the university | Gottingen Type Wind Tunnel | Type: Gottingen Type Horizontal Blower Outlet Dimensions: 1,000 × 1,000mm Wind Velocity: 5 to 50m/s 6-Component Balance is Attached |
| 1989 | For the university | Environmental Testing Wind Tunnel | Type: Gottingen Type Vertical Blower Outlet Dimensions: 1,500 × 1,000mm Wind Velocity: 1 to 10m/s |
| 1990 | For the university | Gottingen Type Wind Tunnel | Type: Gottingen Type Horizontal Blower Outlet Dimensions: 1,000 × 1,000mm Wind Velocity: 5 to 50m/s 6-Component Balance is Attached |
| 1992 | For the laboratory | Low-Speed Aerodynamic Experimental Facility | Type: Gottingen Type Horizontal Blower Outlet Dimensions: 2,500mm × 4,000mm Wind Velocity: 2 to 70m/s |
| 1992 | For the company | Large Volume Airflow Measuring Facility | Type: Blow-off Measuring Section: × 1m Wind Flow Rate: 200 to 10,000 m³/h |
| *1996 | For the university | Gale Simulation Wind Tunnel | Type: Gottingen Type Vertical Measuring Section Type: Closed and Open Blow Outlet Dimensions: 1.8 × 1.5m Measuring Section Length: 11m Ground Noise Level: Less than 60dB (When the Wind Velocity is 15m/s) Attached with 6-Component Balance, 3-Component Balance, Spring Suspender, Electromagnetic Vibrating and Damping Device, Turn Table, and Traverser System |
| 1998 | For the university | Gottingen Type Wind Tunnel | Type: Gottingen Type Closed Circuit Horizontal Measuring Section Type: Closed and Open Blower Outlet Dimension: 500mm Square Measuring Section Length: 1,000mm Wind Velocity: 5 to 50m/s Attached with 6-Component Balance, Turn Table |
| - | - | Large-size Wind Tunnel for Architectural Researches(in the planning stage) | Type: Gottingen Type Closed Circuit Horizontal Blower Outlet Dimensions 1st Measuring Section: 4m × 2.5m 2nd Measuring Section: 5m × 5m Measuring Section Length 1st Measuring Section: 25m 2nd Measuring Section: 20m Wind Velocity 1st Measuring Section: 5 to 50m/s 2nd Measuring Section: 2 to 16m/s |