Steam Generator

The steam generator produces steam. The steam generator separating the reactor system from the turbine system plays a crucial role in maintaining the reliability of the entire PWR plant. Since producing its first unit in 1970 for the Mihama Unit 2, Mitsubishi have continuously improved the design. More than 100 steam generators, including replacement units, have been manufactured and delivered.

Steam Generator Schematics(Model 70F-1)
Specifications of Steam Generators
  Model 54F Model 70F-1
Shell Outer Diameter Upper shell(m) approx. 4.5 approx. 5.1
Lower shell(m) approx. 3.4 approx. 3.9
Total Height(m) approx. 21 approx. 21
Heat Transfer Tubes Number of tubes(No./Unit) 3,386 5,830
Outer diameter(mm) approx. 22.2 19.1
Wall thickness(mm) approx. 1.3 approx. 1.1
Heat Transfer Area(m2/Unit) approx. 5,060 approx. 6,500
Weight(ton) approx. 330 approx. 440

Business contact: Nuclear Energy Systems Nuclear Energy Systems Administration Department Planning Group +81-3-6716-4812