Top of page. Skip to main contents. Skip to main menu. Skip to footer.

HOME > Products > Industrial Machinery > Vertical and L-shaped gas turbine for driving pumps > Special features of vertical type and L-shaped gas turbines
Main contents start here.

Special features of vertical type and L-shaped gas turbines

Special features Effect
Light and compactTD11 •Reduction of space in Pump Station
By installing the gas turbine right over the pump, the space in Pump Station is reduced.
•Simplified housing structure
Since the floor for installation of the gas turbine is unnecessary, the two-floor structure is simplified to the one-floor type.
High reliability •Simplified incidental facilities
The water-cooling facility is unnecessary due to air-cooling.
•Long time operation is possible.
Highly reliable due to the aircraft diversion type gas turbine
Simple operation •Special operation is unnecessary.
No special training is required since operation can be made with one button.
Short starting time •Prepared for immediate operation in case of emergency
Prepared for immediate operation when the urban area is suddenly flooded.
Small vibration and low noise •Measures for the surrounding environment can be easily prepared.
Measures can be easily taken in the urban area where small vibration and low noise are required.

Structure

Package type number MAF-MGM500V MGM1000V MGM3000V MGM4000V MFT-8
Package sizes Length 1600mm 2000mm 2500mm 2600mm 7850mm
Width 1600mm 2000mm 2600mm 2600mm 3200mm
Height 2500mm 4000~4500mm 5220~5600mm 5320~5700mm 4325mm
Package weight 3200~3500kg 7000~8000kg 22000~27000kg 30000kg 27000kg
Fuel consumption (at rated output) 380g/ps/hr 330g/ps/hr 270g/ps/hr 250g/ps/hr 177g/ps/hr
Type Simple open cycle biaxial type  Simple open cycle triaxial type
Compressor Centrifugal one stage Axial flow 5 stage + centrifugal one stage Axial flow 7 stage + centrifugal one stage Axial flow 7 stage + centrifugal one state Axial flow low pressure 8 stage + high pressure 7 stage
Burner Annular type
Compressor driving turbine Axial flow one stage Axial flow two stage Axial flow two stage Axial flow two stage Axial flow high-pressure one stage + low pressure two stages
Compression ratio 5.2 8.0 8.4 10.2 15
Power turbine Axial flow one stage Axial flow two stage Axial flow two stage Axial flow two stage Axial flow two stage

Output range

Output conditions: atmospheric pressure 920Pa, intake air temperature 37 degrees, intake air resistance 100mmAq, exhaust air resistance 300mmAq

Business contact: Power Systems -

Return to top.
Page Top