Top of page. Skip to main contents. Skip to main menu. Skip to footer.
Main contents start here.

MF-111

Applying a wealth of Experience to Cogeneration
The MF-111, by being designed specifically for cogeneration and combined cycle electric power generation applications and by possessing a modern design firing temperature, has the best cogeneration total-plant performance in its power class.
PERFORMANCE
MF-111A Natural Gas Fuel Oil
Generator Power. kW 12,610 12,220
Heat Rate. LHV kcal/kWh 2,836 2,873
Exhaust Gas Flow. kg/h 174,600 174,700
Exhaust Gas Temp. C 547 547
MF-111B Natural Gas Fuel Oil
Generator Power. kW 14,570 14,130
Heat Rate. LHV kcal/kWh 2,778 2,811
Exhaust Gas Flow. kg/h 202,900 203,100
Exhaust Gas Temp. C 530 530
MF-111 DELIVERY LIST
No. Custormers Rating Fuel Start-up Remarks
1. Mitsubishi Oil 14,000kW Refinery gas/Distillate oil 1986.08 Heat recovery
2. Idemitsu Kousan 12,900kW Refinery gas 1987.03 Heat recovery
3. Mitsubish Rayon 15,400kW LPG/Distillate oil 1987.01 Heat recovery
4. Maruzen Petrochemical 10,490kW Methane gas 1987.07 Heat recovery
fully firing
5. Syowa Sell Sekiyu 12,500kW Refinery gas/LPG 1987.12 Heat recovery
6. Syowa Sell Sekiyu 16,250kW Mixed gas/Distillate oil 1988.12 Heat recovery,
Supplementary firing
7. Asahi Chemical Industry 17,000KW Refinery gas 1989.02 Heat recovery
8. Nippon Petroleum Refining 14,000kW LPG/Distillate oil 1989.02 Heat recovery
(Topping unit)
9. Polyplastics 13,650kW Distillate oil 1989.10 Heat recovery
10. Fuji Photo Film 16,000kW Distillate oil 1990.05 Heat recovery
11. Ishihara Sangyo Kaisha 17,000kW Distillate oil 1990.07 Heat recovery
12. Sumitomo Chemical 17,500kW LPG 1990.07 Heat recovery,
supplementary firing
13. Cosmo Oil 17,500kW Refinery gas/LPG 1990.11 Heat recovery,
fully firing
14. Fuji Photo Film 16,000kW Distillate oil 1991.01 Heat recovery,
supplementary
firing
15. Nippon Steel Chemical 12,250kW LPG 1991.03 Heat recovery
16. Idemitsu Petrochemical 17,500kW Refinery gas/LPG 1992.02 Heat recovery
17. Tuma Turbomach #1 14,570kW Natural gas/Distillate oil 1992.08
18. U.S. Turbine #1 15,200kW Natural gas/Distillate oil 1992.09
19. U.S. Turbine #2 15,200kW Natural gas/Distillate oil 1992.09
20. Kyokuto Petroleum Industry 15,000kW Natural gas/Distillate oil 1992.04 Heat recovery
21. Takeda Chemical Industries 14,100kW Natural gas/Distillate oil 1992.10 Heat recovery,
supplementary firing
22. Mitsubishi Oil 17,000kW Distillate oil 1993.06 Heat recovery
23. Hokuetsu Paper Mills 17,000kW Distillate oil 1993.06 Heat recovery
24. U.S. Turbine #3 14,570kW Refinery gas/Distillate oil 1994.09
25. U.S. Turbine #4 14,570kW Refinery gas/Distillate oil 1994.09
26. Tuma Turbomach #2 14,570kW Natural gas 1995.03
FOB
27. Sumitomo Chemical 17,500kW Town gas 1993.12 Heat recovery,
supplementary firing
28. Tuma Turbomach #3 14,570kW Natural gas 1995.03
FOB
29. Tokushu Paper Manufacturing 16,500kW Distillate oil 1994.07
FOB
22.5MW
Combined cycle
30. Cosmo Oil 17,000kW LPG 1995.03
FOB
Heat recovery,
fully firing
31. Nippon Paperboard 17,000kW Town gas 1995.05 Heat recovery,
supplementary firing
32. Nippon Paperboard
Tokyo Mill No.2 Japan
17,000kW Town gas 1995.05 Heat recovery,
supplementary firing
33. Hokuetsu Paper Mills 17,000kW Town gas 1995.07 Heat recovery,
supplementary firing
34. Tohoku Oil 17,000kW Refinery gas
LPG
1997.03 Heat recovery,
supplementary firing
35. Tuma Turbomach #4 14,570kW Natural gas 1995.10
FOB
Heat recovery,
Fully firing
36. Tuma Turbomach #5 14,570kW Natural gas 1995.12
FOB
37. Tuma Turbomach #6 14,570kW Natural gas 1996.03
FOB
38. Tuma Turbomach #7 14,570kW Natural gas 1996.07
FOB
39. Kyokuto Petroleum Industries 17,000kW LPG
Distillate oil
1997.10
40. U.S. Turbine #5 14,570kW Refinery gas
Distillate oil
1997.02
FOB
Heat recovery
41. Fuji Oil 15,310kW Natural gas
Distillate oil
1998.05 20.8 MW
Combined cycle
42. Tuma Turbomach #8 14,570kW Natural gas
Distillate oil
1998.02
FOB
43. Tuma Turbomach #9 14,570kW Natural gas
Distillate oil
1998.03
FOB
Business contact: Network

Business Segment: Power Systems
Return to top.
Page Top