| Year |
Customer |
Equipment Name |
Specifications |
| 1966 |
For the company |
Radiator Testing Wind Tunnel |
A. Car-Mounted Radiator Test Tunnel
| Type |
Blow-off |
| Measuring Section |
| 800 × 2,000mm |
| Wind Velocity |
| 11 to 108 km/hour |
B. Unmounted Radiator Test Tunnel
| Type |
Blow-off |
| Measuring Section |
| 600 × 600mm |
| Wind Velocity |
| 15 to 144 km/hour |
|
| 1979 |
For our company |
Climatic Wind Tunnel |
| Type |
| Horizontal Gottingen Type |
| Blower outlet dimensions |
|
3×2m |
| Wind Velocity |
| 3 to 130 km/hour |
| Temperature |
-20 to 50°C |
| Relative Humidity |
30 to 80% |
|
| 1981 |
For the company |
High Temperature Testing Wind Tunnel |
| Type Vertical Gottingen Type |
| Blower outlet dimensions |
| 2×1.6m (Variable) |
| Wind Velocity |
| 11 to 202 km/hour |
| Temperature |
30 to 55°C |
|
| 1981 |
For the company |
Low Temperature Testing Wind Tunnel |
| Type Vertical Gottingen Type |
| Blower outlet dimensions |
|
2.7 × 2m |
| Wind Velocity |
| 11 to 119 km/hour |
| Temperature |
-20 to 50°C |
|
| 1981 |
For the laboratory |
Natural Environment Simulator |
| Type Gottingen Type Vertical |
| Blower outlet dimensions |
|
2.4 × 2m |
| Wind Velocity |
0.2 to 2 m/s |
| Temperature |
10 to 35°C |
| Relative Humidity |
30 to 80% |
|
| 1981 |
For the company |
Heat Resistance Testing Laboratory |
| Type Gottingen Type Vertical |
| Blower outlet dimensions |
|
2.4×1.2m |
| Wind Velocity |
| 3 to 150 km/hour |
| Temperature |
20 to 50°C |
| Relative Humidity |
3 to 80% |
|
| 1981 |
For the company |
Small-Size Gottingen Type Wind Tunnel |
| Type |
Gottingen Type |
| Blower outlet dimensions |
|
|
1 × 1m |
| Wind Velocity |
| 2 to 205 km/hour |
| Temperature |
3 to 80°C |
| Relative Humidity |
30 to 90% |
|
| 1981 |
For the company |
Rainfall Simulating Wind Tunnel for High-Speed Running Cars |
| Type |
Blow-off |
| Outlet No.1 |
| Outlet Size |
800×800mm |
| Wind Velocity |
| 11 to 101 km/hour |
| Outlet No.2. |
| Outlet Size |
1800 × 400mm |
| Wind Velocity |
| 22 to 206 km/hour |
| Rainfall Simulator is attached |
|
| 1985 |
For the company |
Field Conditions Simulating Wind Tunnel for Car Air-Conditioners |
| Type Vertical Gottingen Type |
| Blower outlet dimensions |
|
2.2 × 1.5m |
| Wind Velocity |
| 0 to 110 km/hour |
| Temperature |
-25 to 50°C |
| Relative Humidity |
30 to 80% |
|
| 1986 |
For the company |
Radiator Performance Analyzing Wind Tunnel |
| Type |
Blow-off |
| Measuring Section |
| 0.2 to 1W × 0.7H m |
| Airflow Volume |
| 160 to 27,000m3/h |
|
| 1989 |
For the company |
Wind Tunnel for Weather Simulating Chassis Dynamometer Chamber |
| Type Gottingen Type Vertical |
| Blower outlet dimensions |
| 2.25 × 2.2m (Variable) |
| Wind Velocity |
0 to 100 km/hour |
| Temperature |
-20 to 40°C |
|
| 1992 |
For the company |
Heat Exchanging Performance Measuring Wind Tunnel |
| Type |
Open Ciucuit |
| Blower outlet dimensions |
| 280 to 850W ×225 to 600H mm |
| Airflow Rate |
160 to 12,600m3/h |
|
| 1992 |
For the company |
Radiator Performance Analyzing Wind Tunnel |
| Type |
Blow-off |
| Measuring Section |
| 110 to 800W × 140 to 630Hmm |
| Airflow Rate |
140~14,500m3/h |
|
| 1996 |
For the company |
Vehicle-Mounted Automatic Air-Conditioner Performance Test Wind Tunnel |
| Type Gottingen Type Vertical |
| Blower outlet dimensions |
|
2.2 × 1.7m |
| Wind Velocity 0 to 120 km/hour |
| Temperature |
-25 to 50°C |
| Relative Humidity |
30 to 80% |
|
| 1998 |
For the company |
Climatic Wind Tunnel |
| Type Horizontal Gottingen Type |
| Blower outlet dimensions |
|
2.2 × 2.0m |
| Wind Velocity 0 to 150km/hour |
| Temperature |
-30 to 50°C |
| Relative Humidity |
30 to 80% |
|
| 2001 |
For the company |
Car-Mounted Air-Conditioner Testing Wind Tunnel |
| Type Gottingen Type Vertical |
| Blower outlet dimension |
|
3 × 2m |
| Wind Velocity 0 to 120km/h |
| Temperature |
-40 to +60°C |
| Relative Humidity |
30 to 80%RH |
|
| 2002 |
For the company |
Climatic Wind Tunnel |
| Type Gottingen Type Vertica |
| Blower outlet dimensions |
| 2.25×2.25 to 2.25×1.20m |
| Wind Velocity 0 to 250km/h |
| Temperature |
-35 to +60°C |
| Relative Humidity |
30 to 80%RH |
|
| 2002 |
For the company |
Fan Wind Tunnel |
| Type Blow-down |
| Measuring section 1000mm |
| Max. flow rate 80-10000m3/h |
|