Top of page. Skip to main contents. Skip to main menu. Skip to footer.

Main contents start here.

Supply Result

Year Customer Equipment Name Specifications
1966 For the company Radiator Testing Wind Tunnel A. Car-Mounted Radiator Test Tunnel
Type Blow-off
Measuring Section
800 × 2,000mm
Wind Velocity
11 to 108 km/hour

B. Unmounted Radiator Test Tunnel
Type Blow-off
Measuring Section
600 × 600mm
Wind Velocity
15 to 144 km/hour
1979 For our company Climatic Wind Tunnel
Type
Horizontal Gottingen Type
Blower outlet dimensions
3×2m
Wind Velocity
3 to 130 km/hour
Temperature -20 to 50°C
Relative Humidity 30 to 80%
1981 For the company High Temperature Testing Wind Tunnel
Type Vertical Gottingen Type
Blower outlet dimensions
2×1.6m (Variable)
Wind Velocity
11 to 202 km/hour
Temperature 30 to 55°C
1981 For the company Low Temperature Testing Wind Tunnel
Type Vertical Gottingen Type
Blower outlet dimensions
2.7 × 2m
Wind Velocity
11 to 119 km/hour
Temperature -20 to 50°C
1981 For the laboratory Natural Environment Simulator
Type Gottingen Type Vertical
Blower outlet dimensions
2.4 × 2m
Wind Velocity 0.2 to 2 m/s
Temperature 10 to 35°C
Relative Humidity 30 to 80%
1981 For the company Heat Resistance Testing Laboratory
Type Gottingen Type Vertical
Blower outlet dimensions
2.4×1.2m
Wind Velocity
3 to 150 km/hour
Temperature 20 to 50°C
Relative Humidity 3 to 80%
1981 For the company Small-Size Gottingen Type Wind Tunnel
Type Gottingen Type
Blower outlet dimensions
1 × 1m
Wind Velocity
2 to 205 km/hour
Temperature 3 to 80°C
Relative Humidity 30 to 90%
1981 For the company Rainfall Simulating Wind Tunnel for High-Speed Running Cars
Type Blow-off
Outlet No.1
Outlet Size 800×800mm
Wind Velocity
11 to 101 km/hour
Outlet No.2.
Outlet Size 1800 × 400mm
Wind Velocity
22 to 206 km/hour
Rainfall Simulator is attached
1985 For the company Field Conditions Simulating Wind Tunnel for Car Air-Conditioners
Type Vertical Gottingen Type
Blower outlet dimensions
2.2 × 1.5m
Wind Velocity
0 to 110 km/hour
Temperature -25 to 50°C
Relative Humidity 30 to 80%
1986 For the company Radiator Performance Analyzing Wind Tunnel
Type Blow-off
Measuring Section
0.2 to 1W × 0.7H m
Airflow Volume
160 to 27,000m3/h
1989 For the company Wind Tunnel for Weather Simulating Chassis Dynamometer Chamber
Type Gottingen Type Vertical
Blower outlet dimensions
2.25 × 2.2m (Variable)
Wind Velocity 0 to 100 km/hour
Temperature -20 to 40°C
1992 For the company Heat Exchanging Performance Measuring Wind Tunnel
Type Open Ciucuit
Blower outlet dimensions
280 to 850W ×225 to 600H mm
Airflow Rate 160 to 12,600m3/h
1992 For the company Radiator Performance Analyzing Wind Tunnel
Type Blow-off
Measuring Section
110 to 800W × 140 to 630Hmm
Airflow Rate 140~14,500m3/h
1996 For the company Vehicle-Mounted Automatic Air-Conditioner Performance Test Wind Tunnel
Type Gottingen Type Vertical
Blower outlet dimensions
2.2 × 1.7m
Wind Velocity 0 to 120 km/hour
Temperature -25 to 50°C
Relative Humidity 30 to 80%
1998 For the company Climatic Wind Tunnel
Type Horizontal Gottingen Type
Blower outlet dimensions
2.2 × 2.0m
Wind Velocity 0 to 150km/hour
Temperature -30 to 50°C
Relative Humidity 30 to 80%
2001 For the company Car-Mounted Air-Conditioner Testing Wind Tunnel
Type Gottingen Type Vertical
Blower outlet dimension
3 × 2m
Wind Velocity 0 to 120km/h
Temperature -40 to +60°C
Relative Humidity 30 to 80%RH
2002 For the company Climatic Wind Tunnel
Type Gottingen Type Vertica
Blower outlet dimensions
2.25×2.25 to 2.25×1.20m
Wind Velocity 0 to 250km/h
Temperature -35 to +60°C
Relative Humidity 30 to 80%RH
2002 For the company Fan Wind Tunnel
Type Blow-down
Measuring section 1000mm
Max. flow rate 80-10000m3/h

Return to top.